AJUNTAMENT D'ALCOI
Website
Generalitat Valenciana
Website
Ayuntamiento de Valencia
Website
Cicloplast
Website
Ayuntamiento de Onil
Website
Anarpla
Website
Ayuntamiento de Mislata
Website
nlWA, North London Waste Authority
Website
Ayuntamiento de Salinas
Website
Zicla
Website
Fondazione Ecosistemi
Website
PEFC
Website
ALQUIENVAS
Website
DIPUTACI� DE VAL�NCIA
Website
AYUNTAMIENTO DE REQUENA
Website
UNIVERSIDAD DE ZARAGOZA
Website
OBSERVATORIO CONTRATACIÓN PÚBLICA
Website
AYUNTAMIENTO DE PAIPORTA
Website
AYUNTAMIENTO DE CUENCA
Website
BERL� S.A.
Website
CM PLASTIK
Website
TRANSFORMADORES INDUSTRIALES ECOL�GICOS
INDUSTRIAS AGAPITO
Website
RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Computational fluid dynamics-based optimal installation strategy of air purification system to minimize NOX exposure inside a public bus stop
At public bus stops, NOX pollutants discharged by regularly stopping buses quickly accumulate, exposing waiting passengers to high levels of air pollutants, which creates a threat to public health. The environmental protection agency (EPA) presents air quality standards for NOX, a significant pollutant that causes lung diseases such as asthma when exposed to the human body. To handle this problem, air purification systems are installed inside bus stops in many public places. However, it is challenging to maintain a low concentration of NOX inside public bus stops due to the persistent inflow of bus exhaust gas. Therefore, it is crucial to design an optimal location for an air purification system to meet air environment standards for respiratory areas. This study proposed a computational fluid dynamics (CFD)-based optimal installation strategy for an air purification system to minimize NOX exposure inside a public bus stop. The CFD model was developed to numerically analyze NO2 exposure with the actual design value for a public bus stop in Ulsan, South Korea. The local NO2 concentration was evaluated in the human breathing zone. The case study was performed according to the locations of the inlet and outlet of the air purification system. A transient CFD simulation was performed to analyze the effect of the air purification system on pollutants generated from the stationary bus by time flow in various cases. NO2 concentration and exposure reduction effectiveness (ERE) were analyzed and compared for each case in the breathing zone. In the optimal case, the ERE of NO2 was confirmed to be 35.9?%, and the NO2 concentration according to the air quality standards of EPA could be maintained at 0.1?ppm or less. The theoretical framework proposed in this study can be generalized to design air purification systems for general external facilities.
» Author: Yup Yoo, Jaeseop Kim, Seongbin Ga, Jonghun Lim, Junghwan Kim, Hyungtae Cho
» Publication Date: 01/11/2022
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es