
AJUNTAMENT D'ALCOI
Website

Generalitat Valenciana
Website

Ayuntamiento de Valencia
Website

Cicloplast
Website

Ayuntamiento de Onil
Website

Anarpla
Website

Ayuntamiento de Mislata
Website

nlWA, North London Waste Authority
Website

Ayuntamiento de Salinas
Website

Zicla
Website

Fondazione Ecosistemi
Website

PEFC
Website

ALQUIENVAS
Website

DIPUTACI� DE VAL�NCIA
Website

AYUNTAMIENTO DE REQUENA
Website

UNIVERSIDAD DE ZARAGOZA
Website

OBSERVATORIO CONTRATACIÓN PÚBLICA
Website

AYUNTAMIENTO DE PAIPORTA
Website

AYUNTAMIENTO DE CUENCA
Website

BERL� S.A.
Website

CM PLASTIK
Website

TRANSFORMADORES INDUSTRIALES ECOL�GICOS

INDUSTRIAS AGAPITO
Website

RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Experimental analysis of the performance of the air supply system in a 120?kW polymer electrolyte membrane fuel cell system
For analyzing the performance of 120?kW polymer electrolyte membrane fuel cell (PEMFC) system and its air supply system, an air system test bench was built, then applied on a 120?kW PEMFC system test bench composed of air supply subsystem, hydrogen supply subsystem, stack, cooling subsystem and electronic control subsystem. The strategy composed of feedforward table and Piecewise proportional integral (PI) feedback control strategy is employed to regulate the flow rate and pressure of air supply system. Firstly, the air compressor map and the mapping relationship between the speed of air compressor, opening of back-pressure valve and stack current are obtained by carrying out experiments on the PEMFC air system bench. Then, the max output performance, steady-state performance, the startup performance, the dynamic response abilities of PEMFC system are tested, respectively. During the experiments, performances under different test conditions were analyzed by comparing parameters such as voltage inconsistency, average voltage, minimum voltage, voltage range, net power of the PEMFC system, and stack power. The test results show that the air supply system can provide qualified flow rate and pressure for the PEMFC stack. The peak power of the stack is 120?kW and net power of the system is 97?kW when the current is 538 A. The response time from rated net power to idle net power is 12?s and from idle net power to rated net power is 23?s. The overshoot of average voltage and minimum voltage in the process of increasing load is both 0.01?V, which are 0.015?V and 0.02?V lower than that when the load is decreased, respectively. The dynamic response speed and stability of the PEMFC system in the process of decreasing the load are better than those in the process of increasing the load.

» Author: Baitao Zhang, Xuhui Wang, Dapeng Gong, Sichuan Xu
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es
