AJUNTAMENT D'ALCOI
Website
Generalitat Valenciana
Website
Ayuntamiento de Valencia
Website
Cicloplast
Website
Ayuntamiento de Onil
Website
Anarpla
Website
Ayuntamiento de Mislata
Website
nlWA, North London Waste Authority
Website
Ayuntamiento de Salinas
Website
Zicla
Website
Fondazione Ecosistemi
Website
PEFC
Website
ALQUIENVAS
Website
DIPUTACI� DE VAL�NCIA
Website
AYUNTAMIENTO DE REQUENA
Website
UNIVERSIDAD DE ZARAGOZA
Website
OBSERVATORIO CONTRATACIÓN PÚBLICA
Website
AYUNTAMIENTO DE PAIPORTA
Website
AYUNTAMIENTO DE CUENCA
Website
BERL� S.A.
Website
CM PLASTIK
Website
TRANSFORMADORES INDUSTRIALES ECOL�GICOS
INDUSTRIAS AGAPITO
Website
RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Degradation of imidacloprid by UV-activated persulfate and peroxymonosulfate processes: Kinetics, impact of key factors and degradation pathway
UV-activated persulfate (UV/PS) and peroxymonosulfate (UV/PMS) processes as alternative methods for removal of imidacloprid (IMP) were conducted for the first time. The reaction rate constants between IMP and the sulfate or hydroxyl radical were calculated as 2.33?109? or 2.42?1010?M?1?s?1, respectively. The degradation of IMP was greatly improved by UV/PS and UV/PMS compared with only UV or oxidant. At any given dosage, UV/PS achieved higher IMP removal rate than UV/PMS. The pH range affecting the degradation in the UV/PS and UV/PMS systems were different in the ranges of 6?8 and 9 to 10. SO42?, F? and NO3? had no obvious effect on the degradation in the UV/PS and UV/PMS systems. CO32? and PO43? inhibited the degradation of IMP in the UV/PS system, while they enhanced the degradation in the UV/PMS system. Algae organic matters (AOM) were used to consider the impact of the degradation of IMP for the first time. The removal of IMP were restrained by both AOM and natural organic matters. The higher removal rate of IMP demonstrated that both UV/PS and UV/PMS were suitable for treating the water containing IMP, while UV/PS was cost-effective than UV/PMS based on the total cost calculation. Finally, the degradation pathways of IMP were proposed.
Graphical abstract» Author: Qiongfang Wang, Pinhua Rao, Guanghui Li, Lei Dong, Xin Zhang, Yisheng Shao, Naiyun Gao, Wenhai Chu, Bin Xu, Na An, Jing Deng
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es