
AJUNTAMENT D'ALCOI
Website

Generalitat Valenciana
Website

Ayuntamiento de Valencia
Website

Cicloplast
Website

Ayuntamiento de Onil
Website

Anarpla
Website

Ayuntamiento de Mislata
Website

nlWA, North London Waste Authority
Website

Ayuntamiento de Salinas
Website

Zicla
Website

Fondazione Ecosistemi
Website

PEFC
Website

ALQUIENVAS
Website

DIPUTACI� DE VAL�NCIA
Website

AYUNTAMIENTO DE REQUENA
Website

UNIVERSIDAD DE ZARAGOZA
Website

OBSERVATORIO CONTRATACIÓN PÚBLICA
Website

AYUNTAMIENTO DE PAIPORTA
Website

AYUNTAMIENTO DE CUENCA
Website

BERL� S.A.
Website

CM PLASTIK
Website

TRANSFORMADORES INDUSTRIALES ECOL�GICOS

INDUSTRIAS AGAPITO
Website

RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Degradation of imidacloprid by UV-activated persulfate and peroxymonosulfate processes: Kinetics, impact of key factors and degradation pathway
UV-activated persulfate (UV/PS) and peroxymonosulfate (UV/PMS) processes as alternative methods for removal of imidacloprid (IMP) were conducted for the first time. The reaction rate constants between IMP and the sulfate or hydroxyl radical were calculated as 2.33?109? or 2.42?1010?M?1?s?1, respectively. The degradation of IMP was greatly improved by UV/PS and UV/PMS compared with only UV or oxidant. At any given dosage, UV/PS achieved higher IMP removal rate than UV/PMS. The pH range affecting the degradation in the UV/PS and UV/PMS systems were different in the ranges of 6?8 and 9 to 10. SO42?, F? and NO3? had no obvious effect on the degradation in the UV/PS and UV/PMS systems. CO32? and PO43? inhibited the degradation of IMP in the UV/PS system, while they enhanced the degradation in the UV/PMS system. Algae organic matters (AOM) were used to consider the impact of the degradation of IMP for the first time. The removal of IMP were restrained by both AOM and natural organic matters. The higher removal rate of IMP demonstrated that both UV/PS and UV/PMS were suitable for treating the water containing IMP, while UV/PS was cost-effective than UV/PMS based on the total cost calculation. Finally, the degradation pathways of IMP were proposed.
Graphical abstract
» Author: Qiongfang Wang, Pinhua Rao, Guanghui Li, Lei Dong, Xin Zhang, Yisheng Shao, Naiyun Gao, Wenhai Chu, Bin Xu, Na An, Jing Deng
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es
