
AJUNTAMENT D'ALCOI
Website

Generalitat Valenciana
Website

Ayuntamiento de Valencia
Website

Cicloplast
Website

Ayuntamiento de Onil
Website

Anarpla
Website

Ayuntamiento de Mislata
Website

nlWA, North London Waste Authority
Website

Ayuntamiento de Salinas
Website

Zicla
Website

Fondazione Ecosistemi
Website

PEFC
Website

ALQUIENVAS
Website

DIPUTACI� DE VAL�NCIA
Website

AYUNTAMIENTO DE REQUENA
Website

UNIVERSIDAD DE ZARAGOZA
Website

OBSERVATORIO CONTRATACIÓN PÚBLICA
Website

AYUNTAMIENTO DE PAIPORTA
Website

AYUNTAMIENTO DE CUENCA
Website

BERL� S.A.
Website

CM PLASTIK
Website

TRANSFORMADORES INDUSTRIALES ECOL�GICOS

INDUSTRIAS AGAPITO
Website

RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Influence of opening and closing process of sliding door on interface airflow characteristic in operating room
Indoor air environment inside operating room (OR) is crucial for the success of surgical operation. The opening and closing process of sliding door is very common in OR. In this case, the designed positive pressure will disappear. Since the air exchange characteristic at the interface of the sliding door will influence the Surgical Site Infection risk, the combined effects of temperature and pressure differences on interface airflow along with the air infiltration volume and intruding particles caused by the airflow are studied by theoretical and numerical methods. Two different cases are compared, where the temperature of OR is lower or higher than that of anteroom, respectively. Results show that the contaminants accumulate in the upper space of the OR due to the airflow pattern between two rooms when the temperature of OR is lower than the anteroom. This will increase the possibility that airflow carrying contaminants intrudes into OR. On the contrary, the contaminants are controlled in the lower space of the OR when the temperature of OR is higher than that of anteroom. On average, the particle intrusion ratio of the second case decreases by 55% compared with that of the first case. So, it is helpful to protect the clean environment of OR when the temperature of OR is higher than that of the anteroom. Moreover, the air infiltration volume of the closing phase is found unequal to that of the opening phase. This study provides the useful information for maintaining a clean indoor environment under operational condition.

» Author: Bin Zhou, Lili Ding, Fei Li, Ke Xue, Peter V. Nielsen, Yang Xu
» Reference: 10.1016/j.buildenv.2018.08.050
» Publication Date: 30/08/2018
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es
