AJUNTAMENT D'ALCOI
Website
Generalitat Valenciana
Website
Ayuntamiento de Valencia
Website
Cicloplast
Website
Ayuntamiento de Onil
Website
Anarpla
Website
Ayuntamiento de Mislata
Website
nlWA, North London Waste Authority
Website
Ayuntamiento de Salinas
Website
Zicla
Website
Fondazione Ecosistemi
Website
PEFC
Website
ALQUIENVAS
Website
DIPUTACI� DE VAL�NCIA
Website
AYUNTAMIENTO DE REQUENA
Website
UNIVERSIDAD DE ZARAGOZA
Website
OBSERVATORIO CONTRATACIÓN PÚBLICA
Website
AYUNTAMIENTO DE PAIPORTA
Website
AYUNTAMIENTO DE CUENCA
Website
BERL� S.A.
Website
CM PLASTIK
Website
TRANSFORMADORES INDUSTRIALES ECOL�GICOS
INDUSTRIAS AGAPITO
Website
RUBI KANGURO
Website
If you want to support our LIFE project as a STAKEHOLDER, please contact with us: life-future-project@aimplas.es
In this section, you can access to the latest technical information related to the FUTURE project topic.
Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a
The objective of this study is to investigate the performance characteristics of an R600a domestic refrigerator-freezer (RF) adopting a condenser outlet split (COS) ejector cycle. Experiments are conducted to measure the performances of conventional and COS ejector-based domestic RFs using R600a. A test bench is used to analyze the pressure lifting effect, mass flow rate variation, and coefficient of performance (COP) improvement with respect to the entrainment ratio (ER). For entire cycle operation at similar cooling capacity condition, the overall COP improvement of the test bench adopting COS ejector cycle over the baseline cycle is 11.4% at the ER of 0.18. Moreover, the COS ejector-based domestic RF is tested to examine its feasibility in actual applications. The COS ejector-based domestic RF with a compressor speed of 1450?rpm exhibits a temperature profile in the freezer compartment that is similar to that of the baseline domestic RF. At similar cooling capacity condition, the energy consumption of the COS ejector-based domestic RF with the compressor speed of 1450?rpm is 10.9% lower than that of the baseline domestic RF, owing to the pressure lifting effect.
» Author: Yongseok Jeon, Dongwoo Kim, Jongho Jung, Dong Soo Jang, Yongchan Kim
» Reference: 10.1016/j.energy.2018.08.007
» Publication Date: 15/10/2018
C/ Gustave Eiffel, 4
(València Parc Tecnològic) - 46980
PATERNA (Valencia) - SPAIN
(+34) 96 136 60 40
Project Management department - Sustainability and Industrial Recovery
life-future-project@aimplas.es